If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. Hi! I hope someone out there could answer what's probably a really simple issue. We have a hometronic HCM200D controller and several HR80 radiator heads. midea air conditioner The system as far as I can tell is set up with optimisation enabled for all zones, but the setpoints only ever seem to change dead on time, even if a room is freezing, and you would expect an earlier change... The HR80s are installed as a room and also as a temperature sensor, so the system can see all the room temps... midea air conditioner Any help would be appreciated... Cheers midea air conditioner
your HR80's using V1.1 firmware or V2? If V1.1 then have you changed the room parameters for max & minimum setpoint? If they are left at the defaults of min=5, midea air conditioner max=30 then optimisation does not work even when selected. Setting to any values above min and less than max should make optimisation work. You can check the firmware version by removing the HR80 from it's coupling and briefly pressing the "teach in" button on the base. Should midea air conditioner read either pwr radiators V1.01 or V2.00 HTH Neil B. Maximum & minimum setpoints sound fine and V2 firmware has no reported problems pwr radiators with optimisation. Are you saying that the HR80's are only switching on at the fixed occupancy time regardless of the room temperature/setpoint or is it simply that the HR80 starts heating the room using optimum start but setpoint on the display does not change until the occupancy time is met? If it's the former I'll double check the documentation to see if there is anything else that could prevent optimum start, if it's the latter it will be a "feature" of the system. pwr radiators I can also post the question pwr radiators to Honeywells midea air conditioner Hometronic midea air conditioner project midea air conditioner pwr radiators team in Germany once I know exactly what the issue is. as far as i'm aware only switching at the setpoints. Smack on 6pm bathroom will open the valve regardless of temp in the room, which is correctly reported. Only other thing that we're doing is having bathroom at 17 for most of the day then 21 at 6pm then 17 at 6.45 - so quite a short time.. for example... but most other rooms are more conventional midea air conditioner and same problem. I'm guessing midea air conditioner that it is correct to add HR80s to both the zone and as a sensor? Do they need to be added as a setpoint too? I have one that has done this somehow but doesn't seem to reflect in the setpoint on the HCM if changed on the HR80 anyway... Cheers Nick The HR80 only needs to be bound to the room under heating/cooling for the module to work correctly. Binding as a room sensor allows you to read back the temperature at the HCM200D. midea air conditioner If you have more than 1 HR80 in a room then only 1 can be used as a sensor, and this sensor is used to control all HR80s in that room i.e. it disables the internal sensor from being used by these HR80s. It should midea air conditioner not be possible to bind an HR80 as a setpoint midea air conditioner adjuster so it could be something has not worked correctly in the binding for that room. Here it would be best to deinstall the setpoint pwr radiators adjuster and room sensor pwr radiators & rebind. pwr radiators Could you set up some tests and note the operation? You could use an occupied setpoint that is much higher than normal and check that the actual temperature midea air conditioner is some way beloew this before the occupied time is reached. midea air conditioner You can then check to see if the HR80 allows the radiator to be heated before occupancy time is reached and note the room temperature midea air conditioner response as well. In the meantime I will ask the project team if there are any circumstances that would prevent optimum start from activating
and report back. Hi pwr radiators midea air conditioner Nick Can you check the firmware version number via the menus on the HCM200D, the project team have asked specifically so this could be important - I think it is under the display menu from memory. Quick Navigation Heating Control Top Site Areas Settings Private Messages Subscriptions Who's Online Search pwr radiators Forums Forums Home Forums General General Discussion Idratek Heating Control X10 xAP xAP Flash Z-Wave CBus KAT5 HomeVision Projects FirM Site News & Events Announcements Meetings Buying Or Selling Bargains Buy / Sell Bulk Buys Commercial Offers Special Forums (email to apply for membership) Trade Only Mark McCall - Automated Home
▼ 2012 (229) ▼ October (169) dettson stop decently, but the rear is no. Pleased... backrest, winch, tow bar, alloy wheels, 12-volt pl... be sure to check out the FAQ by clicking the link ... intelligence. Humanity today, collectively, karnis... If this is your first visit, be sure to check out ... Honeywell has signed an $8.3 million contract with... In 2011, Honeywell s UOP announced a similar proje... As the main automation vendor, Honeywell Process
No comments:
Post a Comment