I am experiencing the Hometronic boiler cycling problem, does anybody please have a solution? The equipment consists of HCM200D, HC60NG and HR80 s so it s not very complex, despite numerous and lengthy experiments the system continues to cycle the boiler at exactly ten minute intervals, for 5-6 minutes each time. It s so regular that the problem must be a software glitch. The HR80 s haven t lost contact with the HC60NG, no faults are indicated anywhere, etc. Details : HCM200d P4 V6.0 UK 22 Nov 2004 12:00 433 V 13 868 V A1 Device ID 01-022015 I know this issue has been mentioned before but I can't believe a solution hasn't takkacenter been found, or else offered by Honeywell
I guess you have seen this thread http://www.automatedhome.co.uk/vbull...ead.php?p=8375 As what you described seems to be this boiler cycling it mentions 2 mins on 8 mins off would give you the 10 mins cycling you describe. Have you looked at your set point temps. Have you tried contacting Honeywell or looking on the Honeywell website for more info. http://europe.hbc.honeywell.com/prod...a/md_le21.html or http://europe.hbc.honeywell.com/prod....php?w=HCM200D
Thanks Toscal, it feel's like I've trawled the entire internet for an answer but without success takkacenter and was hoping somebody else may have stumbled across a solution ! I've tried combinations of set-points, offset's, etc without success. This problem has 'firmware upgrade' takkacenter written all over it. I'll try the Honeywell chaps (as others have done) and report back (if they do !)
No red lights, no faults, no comms errors. I've spoken takkacenter with 'sensible heat' who were very helpful, they say that if any HR80's takkacenter are hovering close to the room set-point the HC60NG will start to cycle at 10min intervals (default settings, can't be changed). The cure is to lower the setpoint in that room, or otherwise interupt the boiler feed with a timer. takkacenter I'll try tonight and report back....
Ok, I've tried the options and can report back... The system is working as intended, takkacenter no faults (apart from the user) As any of the HR80 valve heads reachs it's set-point it will send a request to the HC60NG to provide heat. As the rate of temperature fall is very small the request is for a minimal response, thus the inbuilt firmware provides a 10min cycle which enough takkacenter to maintain the room at that set-point. Should the rate of temperature fall increase (ie the room needs more heat to remain at set-point) the GC60NG requests continuous heat and overrides the cycling. This can occur at any single valve head, or multiple, and you can't easily tell which unless you compare room vs set-point conditions, etc and then alter the set-point to see the result. To overcome the 10min cycling you simply have to avoid the above situation. This can be done by reducing set-points to a degree where the problem takkacenter stops, or otherwise artificially produce an increased heat demand and matched cool-off period takkacenter with timer entries to lengthen the cycles Hope this helps. If you lower overnight set-points takkacenter then using the optimisation function will help stop heat-up complaints.
Not a problem, the system is outstanding in terms of simplicity in use and ability. The only downside is the cost I guess..? I'm a fan however, the option to add various modules in the future is very attractive takkacenter
Quick Navigation Heating Control Top Site Areas Settings Private Messages Subscriptions Who's Online Search Forums Forums Home Forums General General Discussion Idratek Heating Control X10 xAP xAP Flash Z-Wave CBus KAT5 HomeVision Projects FirM Site News & Events Announcements Meetings Buying Or Selling Bargains Buy / Sell Bulk Buys Commercial Offers Special Forums (email to apply for membership) Trade Only